EVHRDS EC Compact unit for controlled mechanical ventilation, dehumidification and air handling systems from 300 to 500 m³/h
-BLDC INVERTER-driven rotary compressor.<br /> -High dehumidifying capacity EVHRDS EC 30 - 65l/day EVHRDS EC 50 – 85l/day.<br /> -Software and algorithm to achieve maximum dehumidifying capacity<br /> -Modulating integration air flow rate and dehumidification. The inverter-driven compressor allows for room comfort to be managed with maximum efficiency.
Description
The unit consists of a one-piece structure including every component for correct operation with wide temperature ranges.
Characteristics
The panels are insulated with 6 mm thick polyethylene.
Dual-suction fans with Brushless EC motor.
Very high efficiency and low noise levels in accordance with Erp regulations.
Coarse filters with low pressure drop easily removable on the recirculation air.
Cooling circuit made of brazed copper complete with: high efficiency compressor, filter drier, finned coils, water exchanger, solenoid valves, throttling device, liquid receiver, high pressure switches.
Command electronics
On-board electrical panel with microprocessor and dedicated control. Fan management, motorised recirculation damper management, timed dirty filter management, recirculation and fresh air management. Possibility of controlling the unit with these three solutions:
1: management via external controls and 0...10vdc signal for air flow rate control from minimum to maximum;
2: management via EVCNU remote panel with built-in T/H sensor;
3: MODBUS RTU RS 485 communication.
Use
Versions DC
Version DC all outside air: unit for the dehumidification of the air coming from the heat recovery unit and for the cooling/heating integration to the radiant air conditioning system.
During summer (compressor on) the unit can operate in 2 modes:
- dehumidification: the unit condenses partially in air and partially in water by means of the plate condenser, obtaining dehumidified air;
-dehumidification + Cooling integration: the unit condenses completely in water, thus obtaining dehumidified and cooled air.
During winter (compressor off), the water coil is supplied with hot water from the heating system and behaves like a fan coil with heat recovery unit.
Models:
- EVHRDS EC 30 H K DC
- EVHRDS EC 50 H K DC
Version DC outside air and recirculation: unit for the dehumidification of the air coming partially from the heat recovery unit and partially from the indoor environment, with cooling/heating integration to the radiant air conditioning system.
During summer (compressor on) the unit can operate in 2 modes:
- dehumidification: the unit condenses partially in air and partially in water by means of the plate condenser, obtaining dehumidified air;
-dehumidification + Cooling integration: the unit condenses completely in water, thus obtaining dehumidified and cooled air.
During winter (compressor off), the water coil is supplied with hot water from the heating system and behaves like a fan coil with heat recovery unit.
- EVHRDS EC 30 H R K DC
- EVHRDS EC 50 H R K DC
General data
Grandezza configurazione orizzontale EVHRDS EC 30 EVHRDS EC 50 Alimentazione V/Ph/Hz 230/1/50 Grado di protezione IP IP 20 Portata aria totale m3/h 300 500 Portata aria esterna nominale (versioni R con ricircolo) m3/h 130 190 Perdita di carico lato VMC Pa 31 38 Potenza nominale assorbita ventilatore
ricircolokW 0,1 0,1
Versions DC
(1) Outside air temperature 33°C; relative humidity 50%. room temperature 25°C; relative humidity 50%, water temperature 16°C. Nominal air and water flow rates.
(2) Outside air temperature 33°C; relative humidity 50%. room temperature 25°C; relative humidity 50%, water temperature 16°C. Nominal air and water flow rates.
(3) Room temperature 20°C; relative humidity 50%, nominal air flow rate; Water in 35°C.
VERSIONE DC EVHRD EC 30 EVHRD EC 50 Capacità di deumidificazione utile 1 l/24h 56 89 Potenza frigorifera totale 2 kW 2,6 3,95 Potenza assorbita compressore kW 0,69 0,95 Frequenza compressore Hz 55 73 EER 3,75 4,15 Potenza frigorifera sensibile kW 1,18 1,69 Potenza termica resa 3 kW 0,53 1,15 Portata acqua m3/h 0,12 0,18 Perdita di carico Kpa 9 7 Pressione sonora Lp ad 3 Mt dB(A) 39,5 40,8 Alimentazione elettrica V/Ph/Hz 230/1/50 Corrente massima assorbita in funzionamento A 3,7 5,1 Potenza massima assorbita in funzionamento kW 0,79 1,11 Corrente massima assorbita componenti A 6,78 7 Potenza massima assorbita dai componenti kW 1,49 1,55
Dimensions
| dimensioni | EVHRDS EC 30 | EVHRDS EC 50 | |
| Larghezza A | mm | 690 | 690 |
| Profondità B | mm | 690 | 800 |
| Altezza C | mm | 270 | 320 |
| Ingresso aria di ricircolo DN1 (non presente nella versione senza ricircolo) | mm | 160 | 200 |
| Ingresso aria primaria (dalla macchina di ventilazione) DN2 | mm | 160 | 200 |
| Mandata bxh | mm | 347x177 | 518x252 |
| Attacchi acqua mandata/ritorno | Ø" | 1/2” - 1/2” | 1/2” - 1/2” |
| Diametro scarico condensa | Ø mm | 12 | 12 |
| Peso versione DC | kg | 43 | 56 |
| Peso versione R DC | kg | 46 | 57 |
Supply plenum dimensions
All dimensions are expressed in mm.
| Models | L | H | P | Ø |
| EVHRDS EC 30 | 347 | 177 | 100 | 1x160 |
| EVHRDS EC 50 | 518 | 252 | 100 | 2x160 |
Heat recovery units and accessories price list VERSION K
| Models | versioni senza ricircolo | versioni con ricircolo | accessori | |||||
| DC | R DC | controllo elettronico remoto | umidostato ambiente | Valvola acqua on/off a 2 vie 1/2" | Valvola acqua on/off a 3 vie 1/2" | kit filtri per versioni con ricircolo | Plenum di mandata isolato | |
| EVCNU | UMR | |||||||
| euro | euro | euro | euro | euro | euro | euro | euro | |
| EVHRDS EC 30 | 3.799,99 | 4.174,16 | 296,66 | artRE29002000 | 311,90 | 363,89 | 36,94 | 66,30 |
| EVHRDS EC 50 | 4.078,35 | 4.452,52 | 296,66 | artRE29002000 | 311,90 | 363,89 | 45,14 | 101,87 |